Small Thin Film Analyzer Specifications

Sample Sizes

Standard load based test 3.08cm x 15.3cm (1.21" x 6.02") By special order (3.08cm X 17.78cm)
High load test May require a necked (dog bone) sample, depending on expected load: necked down to 1.50 cm (0.59")
Minimum thickness The actual material properties will determine the minimum thickness.
Maximum thickness 3mm (0.12"), depending on clamp foot design
Short column test (Option) 5.1cm X 3.2cm (2" x 1.25".) This sample size may vary depending on ultimate load potential, flute type etc.
Option 1 Pass through sample preparation punches

Load Range

Internal load frame capacity ±1.3344kN (300 lbf)
A/D conversion 16 bits resolution
Load control 16 bits resolution. NOTE: this device's cross head motion uses load control.
Load ramp rates User selected, computer generated.
Calibration 444.8 N (100 lbf) load ring standard
Option 1 Short column test fixtures.

Extensometer

A precision extensometer is used for motion sensing. Typical setups use 25.4mm (1") gage length 10% extensometer. A/D conversion is at 16 bit resolution.
Option 1 25.4mm (1") gage extender for 5% operations
Option 2 1 - 2mm (micron level) measurement
Option 3 Optical measurements

Software

Option 1 Microsoft® SQL Server® data storage

Relative Humidity

The standard setup is in a 22.8°C (73°F) 50% room. The system can be placed in other environmental conditions, such as a 20% room or a 90% room.  Please contact us for details and suggestions.
Option 1 Below 10% operations
Option 2 Above 95% operations - Condensing water may result in erratic results.

Temperature Control

The standard setup exchanges heat to ambient room conditions.
Standard 22.8°C (73°F); 50% RH.

Connections

Power Typically 120VAC 1 phase 10A 60Hz
Auxiliary inputs Room condition recording.
Vacuum pump exhaust vent Vented outside preferable. 
Option 1 House vacuum if available, may be used.
Option 2 Analog phone line
Option 3 Network connection
Option 4 Printer
Option 5 Alarms

Dimensions

Actual placement requires extra room around the units
Test unit 45.72cm L x 68.58cm W x 22.86cm H (18"L x 27"W x 9"H)
Vacuum cart 50.8cm L x 101.6cm W x 50.8cm H (20"L x 40"W x 20"H)

System configuration and specifications may change without notice.

Delphinus reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in design of its products.  Components made under military approvals will be in accordance with the approval requirements.  The information included herein is believed to be accurate and reliable.  However, Delphinus assumes no responsibility for its use; nor for any infringements of patents or other rights of third parties that may result from its use.

Free Tips:

Hold off a bit purchasing new hardware unless the new equipment is qualified for Microsoft Vista. (7/5/06)

(More tips)

 

News:

(News)

 

Send us a question

Submit technical question.
Top

Send questions and comments about this website to: contact@delphinus-llc.com
© 2006 Delphinus, LLC.  All rights reserved.
 
           
Home Computers Software development Test equipment Contact us About us